What is stratification? Is it more likely to occur at places with low ceilings or places with high ceilings? How does it cause thermal discomfort for a room's occupants? How can stratification be prevented?

Short Answer

Expert verified
Answer: Stratification is the layering of air temperature in a room, where warm air rises towards the ceiling and cold air sinks towards the floor, causing a vertical temperature gradient. It can be minimized in high-ceiling rooms by improving air circulation using devices such as ceiling fans, implementing a zoned heating system, using radiant heating systems, and ensuring proper insulation and sealing of windows and doors.

Step by step solution

01

Understanding Stratification

Stratification is the layering of air temperature in a room or enclosed space, which occurs when warm air rises towards the ceiling and cold air sinks towards the floor. This is due to the natural tendency of warm air to be less dense than cold air, thus causing a vertical temperature gradient in the room.
02

Stratification in Low and High Ceilings

Stratification is more likely to occur in rooms with high ceilings because, in such rooms, there is a larger vertical space for the temperature gradient to develop. In low-ceiling rooms, the warm and cold air layers are closer together, which means more mixing occurs, and the stratification effect is reduced.
03

Thermal Discomfort Caused by Stratification

Stratification causes thermal discomfort for a room's occupants because the temperature varies significantly between the floor and ceiling levels. The floor level, occupied by people, might be too cold, while the ceiling level is much warmer. This uneven distribution of air temperature in the room can cause discomfort for the occupants, as they may feel cold at their feet and warm near their head.
04

Preventing Stratification

Stratification can be prevented or minimized by improving air circulation in the room. Some methods for achieving this include: 1. Installing ceiling fans or other air circulation devices to mix the air in the room, thus preventing the formation of distinct temperature layers. 2. Implementing a zoned heating system, which heats the lower part of the room separately from the upper part, balancing the temperature gradient. 3. Using radiant heating systems, which heat the objects and people directly instead of heating the air, resulting in more even and comfortable temperatures. 4. Ensuring proper insulation and sealing of windows and doors, preventing cold drafts that can enhance stratification.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with Vaia!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

In the metal processing industry, heat treatment of metals is commonly done using electrically heated draw batch furnaces. Consider a furnace that is situated in a room with surrounding air temperature of \(30^{\circ} \mathrm{C}\) and an average convection heat transfer coefficient of $12 \mathrm{~W} / \mathrm{m}^{2}\(. \)\mathrm{K}$. The furnace front is made of a steel plate with thickness of \(20 \mathrm{~mm}\) and a thermal conductivity of $25 \mathrm{~W} / \mathrm{m} \cdot \mathrm{K}$. The outer furnace front surface has an emissivity of \(0.23\), and the inside surface is subjected to a heat flux of $8 \mathrm{~kW} / \mathrm{m}^{2}$. Determine the outside surface temperature of the furnace front.

What is the value of the engineering software packages in \((a)\) engineering education and \((b)\) engineering practice?

In a power plant, pipes transporting superheated vapor are very common. Superheated vapor is flowing at a rate of \(0.3 \mathrm{~kg} / \mathrm{s}\) inside a pipe \(5 \mathrm{~cm}\) in diameter and \(10 \mathrm{~m}\) in length. The pipe is located in a power plant at \(20^{\circ} \mathrm{C}\) and has a uniform surface temperature of \(100^{\circ} \mathrm{C}\). If the temperature drop between the inlet and exit of the pipe is \(30^{\circ} \mathrm{C}\), and the specific heat of the vapor is $2190 \mathrm{~J} / \mathrm{kg} \cdot \mathrm{K}$, determine the heat transfer coefficient as a result of convection between the pipe surface and the surroundings.

A 40-cm-long, 800-W electric resistance heating element with diameter $0.5 \mathrm{~cm}\( and surface temperature \)120^{\circ} \mathrm{C}$ is immersed in \(75 \mathrm{~kg}\) of water initially at \(20^{\circ} \mathrm{C}\). Determine how long it will take for this heater to raise the water temperature to \(80^{\circ} \mathrm{C}\). Also, determine the convection heat transfer coefficients at the beginning and at the end of the heating process.

Consider a house in Atlanta, Georgia, that is maintained at $22^{\circ} \mathrm{C}\( and has a total of \)20 \mathrm{~m}^{2}$ of window area. The windows are double-door type with wood frames and metal spacers and have a \(U\)-factor of \(2.5 \mathrm{~W} / \mathrm{m}^{2} \cdot \mathrm{K}\) (see Prob. 1-120 for the definition of \(U\)-factor). The winter average temperature of Atlanta is \(11.3^{\circ} \mathrm{C}\). Determine the average rate of heat loss through the windows in winter.

See all solutions

Recommended explanations on Physics Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.

Sign-up for free