Chapter 13: Problem 6
13.6D A factory requires \(3750 \mathrm{~kW}\) of electric power and highquality steam at \(107^{\circ} \mathrm{C}\) with a mass flow rate of \(2.2 \mathrm{~kg} / \mathrm{s}\). Two options are under consideration: Option 1: A single boiler generates steam at \(2.0 \mathrm{MPa}, 320^{\circ} \mathrm{C}\), supplying a turbine that exhausts to a condenser at \(0.007\) MPa. Steam is extracted from the turbine at \(107^{\circ} \mathrm{C}\), returning as a liquid to the boiler after use. Option 2: A boiler generates steam at \(2.0 \mathrm{MPa}, 320^{\circ} \mathrm{C}\), supplying a turbine that exhausts to a condenser at \(0.007 \mathrm{MPa}\). A separate process steam boiler generates the required steam at \(107^{\circ} \mathrm{C}\), which is returned as a liquid to the boiler after use. The boilers are fired with natural gas and \(20 \%\) excess air. For \(7200 \mathrm{~h}\) of operation annually, evaluate the two options on the basis of cost.