Chapter 12: Problem 3
In the insulin pump system, the user has to change the needle and insulin supply at regular intervals and may also change the maximum single dose and the maximum daily dose that may be administered. Suggest three user errors that might occur and propose safety requirements that would avoid these errors resulting in an accident.
Short Answer
Step by step solution
Identifying Potential User Error 1
Proposing Safety Requirement 1
Identifying Potential User Error 2
Proposing Safety Requirement 2
Identifying Potential User Error 3
Proposing Safety Requirement 3
Unlock Step-by-Step Solutions & Ace Your Exams!
-
Full Textbook Solutions
Get detailed explanations and key concepts
-
Unlimited Al creation
Al flashcards, explanations, exams and more...
-
Ads-free access
To over 500 millions flashcards
-
Money-back guarantee
We refund you if you fail your exam.
Over 30 million students worldwide already upgrade their learning with Vaia!
Key Concepts
These are the key concepts you need to understand to accurately answer the question.
Safety Requirements
It's important to consider potential errors a user might make, such as setting incorrect dose limits or mishandling system components. For instance, a double-check mechanism is essential when users attempt to set or change insulin doses.
This mechanism could involve confirming changes to limit settings by checking them against historical usage data and alerting users if values fall outside normal parameters.
- Prompts for user confirmation of dose changes
- Warning alerts for atypical settings
- Reminders for supply replenishment
Checks should be in place to detect inconsistencies, alerting the user before any incorrect dosage is delivered. This prevents dosing errors caused by improper needle handling or air residue.
Insulin Pump System
This provides a continuous and controlled method of insulin delivery, thus playing a critical role in managing blood sugar levels over time.
Despite its benefits, there are potential risks if the system is not used correctly. Users must routinely change parts such as needles and insulin supplies. Moreover, they might need to adjust settings for maximum doses, which, if done incorrectly, can lead to health issues like hypoglycemia.
That's why the system also features user-friendly interfaces that remind and guide users through various tasks.
- Automated alerts for supply management
- Guided processes for needle replacement
- Double-check systems for dose adjustments
User Guidance
Successful management of the insulin pump system heavily relies on the user having the right knowledge and instructions at every step.
This includes changing essential components, setting dose limits, and maintaining equipment.
To minimize user errors, the insulin pump should come with an inclusive guiding system. This could involve showing visual prompts or offering auditory cues that walk the user through each essential task.
Another aspect is training users to recognize and respond appropriately to system alerts.
- Step-by-step auditory and visual guides
- Regular updates on system operations and errors
- Hands-on user training initiatives
Hypoglycemia Prevention
Preventing hypoglycemia involves ensuring the user administers the correct amount of insulin at the proper times.
The insulin pump should be equipped with systems that aid in dose management. These systems should verify dose changes against the patient's usual patterns and suggest corrections or confirm choices with the user if anomalies are detected.
Furthermore, the pump can be programmed to alert the user when blood sugar levels suggest hypoglycemia might occur, prompting immediate action.
- Alerts for unusual dosing patterns
- Warnings for potential low blood sugar levels
- Prompt guidance for corrective measures