In either aY-or-Ytransformer, as per the American Standard notation, the negative-sequence phase shift is the reverse of the positive sequence phase shift.

(a) True

(b) False

Short Answer

Expert verified

Therefore, the correct option is (a) True.

Step by step solution

01

Draw the positive and negative phase sequences of three-phase voltages.

Let Va, Vband Vc be the phase voltages in primary side of the Y-transformer and Ya30°, Yb30° and Yc30° be the phase voltages in -Ytransformer.

Draw the positive and negative phase sequence of phase voltages in transformer:

Figure: 1

Draw the positive and negative phase sequence of phase voltages in -Y transformer:

Figure: 2

02

Explanation for phase reverse of positive and negative sequence phase voltages 

From figure 1 and 2, it is clear that the positive sequence of phase voltages is ABC and negative sequence is ACB that is reverse of ABC.

Therefore, the correct option is (a) true.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with Vaia!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

A two-winding single-phase transformer rated 60kVA,240/1200V,60Hzhas an efficiency of 0.96when operated at rated load 0.8, power factor lagging. This transformer is to be utilized as a1440/1200V step-down autotransformer in a power distribution system. (a) Find the permissible kVA rating of the autotransformer if the winding currents and voltages are not to exceed the ratings as a two-winding transformer. Assume an ideal transformer. (b) Determine the efficiency of the autotransformer with the kVA loading of part (a) and 0.8 power factor leading

The ratings of a three-phase three-winding transformer are

Primary (1) : Y connected, 66kV, 15MVA

Secondary (2) : Y connected, 13.2kV, 10MVA

Tertiary (3): A connected, 2.3kV, 5MVA

Neglecting winding resistances and exciting current, the per-unit leakage reactances are

X12 = 0.08on a 15MVA, 66kV base

X13 = 0.10on a 10 MVA, 13.2kV base

X23= 0.09on a 5MVA, 2.3kV base

(a) Determine the reactances X1X2X3 of the equivalent circuit on a 15MVA, 66kV base at the primary terminals. (b) Purely resistive loads of 7.5MW at 13.2kV and 5MW at 2.3kV are connected to the secondary and tertiary sides of the transformer, respectively. Draw the per-unit diagram, showing the per-unit impedances on a 15MVA, 66kV base at the primary terminals.

Match the following.

(i) Hysteresis loss,

(a) Can be reduced by constructing the core with laminated sheets of the alloy steel

(ii) Eddy current loss,

(b) Can be reduced by the use of special high grades of alloy steel as core material.

Consider Figure 3.5. the right. Match the following, those on the left to those on

(i)Im (a) Exciting current
(ii)IC (b) Magnetizing current

(iii)Ie (c) Core loss current

Does an openconnection permit balanced three-phase operation?

(a) Yes

(b) No

See all solutions

Recommended explanations on Computer Science Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.

Sign-up for free