Control chart. A laboratory monitoring perchlorate (CIO-4)in urine measured quality control samples made from synthetic urine spiked withCIO-4. The graph in Box5-2shows consecutive quality control measurements. Are any troubleshooting conditions from Box 5-2 observed in these data?

Short Answer

Expert verified

The troubleshooting conditions for a control chart which is monitoring perchlorate (CIO-4)in urine measured quality control samples made from synthetic urine spiked with(CIO-4)was explained.

Step by step solution

01

Definition of control chart

A Control Chart is a visual representation of the confidence intervals for a Gaussian distribution.

Interpretation:

It is necessary to explain the troubleshooting conditions for a control chart that monitors perchlorate(CIO-4)in urine measured quality control samples made from synthetic urine spiked with.

02

Signs of a process that might be out of control

Six signs that a process might be getting out of control.

1. Keen observation outside the action lines -No

2. There is always 2 out of 3 measurements between action and warning lines-No

3. There are all 7 consecutive measurements above or below the center line-Yes

4. There are all 6 measurements which can be increasing or decreasing where they are located-No

5. There are 14 points which are alternating up and down regardless where they are located-No

6. A nonrandom pattern-No

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with Vaia!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

Internal standard calibration curve. Figure 5-10 is a graph of Ax/Asversus[X]/[S]=(mol%vinylacetateunits)/(mol%ethyleneunits)=q/p in Reaction 5-13.

(d) From the uncertaintyubof the intercept, find the95%confidence interval for the intercept. Does this interval include the theoretical value of zero?

Internal standard graph -- Data are shown below for chromatographic analysis of naphthalene (C10H8), using deuterated naphthalene (C10D8, in which D is the isotope 2H) as an internal standard. The two compounds emerge from the column at almost identical times and are measured by a mass spectrometer.

(a) Using a spreadsheet such asFigure 4-15, prepare a graph of Equation 5-12 showing peak area ratio(C10H8/C10D8)versus concentration ratio role="math" localid="1663559632352" ([C10H8]/C10D8) . Find the least-squares slope and intercept and their standard uncertainties. What is the theoretical value of the intercept? Is the observed value of the intercept within experimental uncertainty of the theoretical value?

(b) Find the quotientrole="math" localid="1663559638520" [C10H8]/[C10D8]for an unknown whose peak area ratio (C10H8/C10D8) is 0.652. Find the standard uncertainty for the peak area ratio.

(c) Here is why we try not to use 3-point calibration curves. For n = 3 data points, there is n - 2 = 1 degree of freedom, because 2 degrees of freedom are lost in computing the slope and intercept. Find the value of Student's for confidence and 1 degree of freedom. From the standard uncertainty in (b), compute the 95 % confidence interval for the quotient[C10H8]/[C10D8] . What is the percent relative uncertainty in the quotient[C10H8]/[C10D8]? Why do we avoid 3-point calibration curves?

Detection limit. A sensitive chromatographic method was developed to measure sub-part-per-billion levels of the disinfectant by-products iodate(IO3-), chlorite(CIO2-), and bromate(BrO3-)in drinking water. As the oxyhalides emerge from the column, they absorption at267nm. For example, each mole of BrO3-+8Br-+6H+R3Br3-+3H2Obromate makes by the reaction

Bromate near its detection limit gave the following chromatographic peak heights and standard deviations (s). For each concentration, estimate the detection limit. Find the mean detection limit. The blank is 0 because chromatographic peak height is measured from the baseline adjacent to the peak. Because blank =0, relative standard deviation applies to both peak height and concentration, which are proportional to each other. Detection limit is 3 s for peak height or concentration.

Internal standard. A solution was prepared by mixing 5.00mLof unknown elementXwith2.00mLof solution containingrole="math" localid="1654777035083" 4.13ฮผgof standard elementSper millilitre, and diluting to10.0mL. The signal ratio in atomic absorption spectrometry was (signal fromX)/ (signal fromS)=0.808. In a separate experiment, with equal concentrations ofXandS, (signal fromX)/signal fromS)=1.31. Find the concentration ofXin the unknown.

Blind Samples: Interpreting Statistics-- The U.S. Department of Agriculture provided homogenized beef baby food samples to three labs for analysis.4Results from the labs agreed well for protein, fat, zinc, riboflavin, and palmitic acid. Results for iron were questionable: Lab A, 1.59ยฑ0.14(13); Lab B, 1.65ยฑ0.56 (8); Lab C, 2.68ยฑ0.78(3) mg/100 g . Uncertainty is the standard deviation, with the number of replicate analyses in parentheses. Use two separate t tests to compare results from Lab Cwith those from Lab A and Lab B at the 95 % confidence level. Comment on the sensibility of the t test results and offer your own conclusions.

See all solutions