Two peaks emerge from a reversed-phase chromatography column as sketched in the illustration.

According to Equation 23-33, resolution is given by

Resolution=N4(α-1)α(k21+k2)

where Nis plate number, αis relative retention (Equation23-20), and k2 is the retention factor for the more retained component (Equation 23-16).

(a) If you decrease the amount of organic solvent in the mobile phase, you will increase retention. Sketch the chromatogram if retention factors increase but Nand αare constant.

(b) If you change the solvent type or the stationary phase, you will change the relative retention. Sketch the chromatogram ifαincreases but Nandk1are constant.

(c) If you decrease particle size or increase column length, you can increase the plate number. Sketch the chromatogram if Nincreases by (i) decreasing particle size and (ii) increasing column length. Assume αand k2are constant.

Short Answer

Expert verified

a)The sketch of chromatogram if retention factors increase but Nand αare constant:

b) The sketch of chromatogram if αincreases but Nand k1are constant:

c) The sketch of chromatogram if Nincreases by (i) decreasing particle size and (ii) increasing column length.

Step by step solution

01

Definition of retention factor.

The retention factor (Rf) is used in thin-layer chromatography to compare and identify substances. The distance travelled by the compound divided by the distance travelled by the solvent front gives the Rf value of a compound.

02

Step 2: The sketch of chromatogram if retention factors increase but   and  are constant.

a)

When the quantity of organic solvent in the mobile phase is reduced, the retention is automatically enhanced. As a result, ifNandαare held constant, the chromatogram will look like this

03

Step 3: The sketch of chromatogram if αincreases butNandk1are constant.

b)

If the solvent or stationery phase is changed, the relative retention will vary. As a result, the chromatogram will look like this:

04

Step 4: The sketch of chromatogram if N increases by (i) decreasing particle size and (ii) increasing column length.

c)

The chromatogram can be produced as shown below if the particle size is reduced and the plate number is increased.

The chromatogram can be obtained as shown below if the column length is raised and the plate number is increased.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with Vaia!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

25-3 What length of column packed with2μmparticles is needed to yield the same plate number as in Fugure 25.12? How long woald the separation take?

After poisonous melamine and cyanuric acid appeared in milk in China (Box11-3) in 2008, there was a flurry of activity to develop methods to measure these substances. An analytical method for milk is to treat 1volume of milk with 9 volumes of H2O2CH3CN(20:80vol/vol)to precipitate proteins. The mixture is centrifuged for 5minto remove precipitate. The supernatant liquid is filtered through a 0.5-μmfilter and injected into a HILIC liquid chromatography column (TSK gel Amide-stationary phase) and products are measured by mass spectrometry with selected reaction monitoring (Section 22-5). Melamine is measured in positive ion mode with the transitionm/z127→85. Cyanuric acid is measured in negative ion mode with the transition m/212842.

(a) Write the formulas for the four ions and propose structures for all four ions.

(b) Even though milk is a complex substance, only one clean peak is observed for melamine and one for cyanuric acid spiked into milk. Explain why

What does it mean for a separation procedure to be ”rugged” and why is it desirable?

Question: Explain how to use a gradient for the first run to decide whether isocratic or gradient elution would be more appropriate.

a. Why are HPLC particles porous?

b. Why are the particles with60-120A°pores used for small molecules but wide pore300-A°stationary phases used to separate polypeptides and proteins?s

See all solutions

Recommended explanations on Chemistry Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.

Sign-up for free