The chromatogram in Box 25-3 shows the supercritical fluid chromatography separation of seven steroids monitored by three detectors.

(a) In the middle chromatogram, ultraviolet detection provides near universal response for the steroids, whereas in the lower chromatogram the ultraviolet detector provides a selective response for a few of the steroids. How can ultraviolet detection act as either a selective or universal detector?

(b) Why is a sloping baseline observed at 210 nm, but the baseline is flat at 254 nm?

(c) Use the baseline disturbance early in the 254 nm chromatogram to measure tm. How does the measured value compare with that predicted using Equation 25-5 given that the column is 25 × 0.46 cm and the flow rate is 2.0 mL/min.

Short Answer

Expert verified

(a)Many chromophores absorb ,210 nm which is in the middle range but only some absorb at 254 nm. So ultraviolet detector acts as universal detector below 210 nm. Above that wavelength it acts as a selective detector.

(b)The increasing gradient of CH3OH absorbs weakly at 210 nm. So,sloping baseline is observed at 210 nm, but the baseline is flat at 254 nm.

(c) The measured value of tm is 1.29 min, and the predicted value of tm is 1.32 min.

Step by step solution

01

Explanation regarding part (a)

In the middle chromatogram, ultraviolet detection provides near universal response for the steroids, whereas in the lower chromatogram the ultraviolet detector provides a selective response for a few of the steroids. An ultraviolet detector using a flow cell such is the most common HPLC detector because many solutes absorb ultraviolet light. Simple systems employing the intense 254-nm emission of a mercury vapor lamp were the backbone of early HPLC systems, but are little used today. More versatile, variable-wavelength detectors have broadband deuterium, xenon, or tungsten lamps and a monochromator, are used now a days. At wavelengths above 210 nm, detection is selective for compounds with an absorbing chromophore. Many compounds absorb wavelengths below 210nm and so ultraviolet detection below 210 nm is nearly universal whereas above that wavelength it acts as a selective detector.

02

Explanation regarding part (b)

The increasing gradient of CH3OH absorbs weakly at 210 nm. So, sloping baseline is observed at 210 nm, but the baseline is flat at 254 nm.

03

Explanation regarding part (c)

For calculating tm the formula need to be used is shown below

tm=Ldc22FL=Columnlengthdc=ColumndiameterF=Flowrate

Therefore, from the given data the following can be calculated

L=25cmdc=0.46cmF=2mL/mintm=25×0.4622×2min=1.29min

The measured value of tm is 1.29 min, and the predicted value of tm is 1.32 min.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with Vaia!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

What does it mean for a separation procedure to be ”rugged” and why is it desirable?

A known mixture of compounds A and B gave the following HPLC results:

A solution was prepared by mixing 12.49mgof Bplus 10.00mLof unknown containing just and diluting to 25.00mL. Peak areas of 5.97and 6.38were observed for AandB, respectively. Find the concentration of A(mg/mL)in the unknown.

Question: Explain how to use a gradient for the first run to decide whether isocratic or gradient elution would be more appropriate.

Two peaks emerge from a reversed-phase chromatography column as sketched in the illustration.

According to Equation 23-33, resolution is given by

Resolution=N4(α-1)α(k21+k2)

where Nis plate number, αis relative retention (Equation23-20), and k2 is the retention factor for the more retained component (Equation 23-16).

(a) If you decrease the amount of organic solvent in the mobile phase, you will increase retention. Sketch the chromatogram if retention factors increase but Nand αare constant.

(b) If you change the solvent type or the stationary phase, you will change the relative retention. Sketch the chromatogram ifαincreases but Nandk1are constant.

(c) If you decrease particle size or increase column length, you can increase the plate number. Sketch the chromatogram if Nincreases by (i) decreasing particle size and (ii) increasing column length. Assume αand k2are constant.

The “rule of three” states that the retention factor for a given solute decreases approximately threefold when the organic phase increases by10%.In figure 25-12,tm=2.7min. Find k for peak 5at 40%B .predict the retention time for peak at B and compare the observed and predicted times.

See all solutions

Recommended explanations on Chemistry Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.

Sign-up for free