Warning: foreach() argument must be of type array|object, bool given in /var/www/html/web/app/themes/studypress-core-theme/template-parts/header/mobile-offcanvas.php on line 20

The antitumor drug gimatecan is available as nearly pure (S)-enantiomer. Neither pure (R)-enantiomer nor a racemic (equal) mixture of the two enantiomers is available. To measure small quantities of (R)-enantiomer in nearly pure (S)-gimatecan, a preparation was subjected to normal-phase chromatography on each of the enantiomers of a commercial, chiral stationary phase designated (S,S)- and (R,R)-DACH-DNB. Chromatography on the (R,R)-stationary phase gave a slightly asymmetric peak at tr 5 6.10 min with retention factor k 5 1.22. Chromatography on the (S,S)- stationary phase gave a slightly asymmetric peak at tr 5 6.96 min with k 5 1.50. With the (S,S) stationary phase, a small peak with 0.03% of the area of the main peak was observed at 6.10 min.

Chromatography of gimatecan on each enantiomer of a chiral stationary phase. Lower traces have enlarged vertical scale. [Data from E. Badaloni, W. Cabri, A. Ciogli, R. Deias, F. Gasparrini, F. Giorgi, A. Vigevani, and C. Villani, “Combination of HPLC ‘Inverted Chirality Columns Approach’ and MS/MS Detection for Extreme Enantiomeric Excess Determination Even in Absence of Reference Samples.” Anal. Chem. 2007, 79, 6013.]

(a) Explain the appearance of the upper chromatograms. Dashed lines are position markers, not part of the chromatogram. What Problems 709 would the chromatogram of pure (R)-gimatecan look like on the same two stationary phases?

(b) Explain the appearance of the two lower chromatograms and why it can be concluded that the gimatecan contained 0.03% of the (R)-enantiomer. Why is the (R)-enantiomer not observed with the (R,R)-stationary phase?

(c) Find the relative retention (a) for the two enantiomers on the (S,S)-stationary phase.

(d) The column provides N 5 6 800 plates. What would be the resolution between the two equal peaks in a racemic (equal) mixture of (R)- and (S)-gimatecan? If the peaks were symmetric, does this resolution provide baseline separation in which signal returns to baseline before the next peak begins?

Short Answer

Expert verified

The part (a), part (b), part (c), part (d) is

a) Chiral stationary phase it will be eluted at 6.10 min.

b) Chromatography enables us to locate where enantiomer is eluted.

c) α=1.26

d)resoluction=2.55

Step by step solution

01

Two stationary phases

Part (a)

If we look (R, R) chiral stationary phase, we see that (S)-gimatecan is eluted at 6.1 min. If we look (S, S) chiral stationary phase, we see that (S)-gimatecan is eluted at 6.96 min which means that it is retained more strongly. (R)-enantiomer of gimatecan should have the opposite behaviour. So, at (R, R) chiral stationary phase, it will be eluted ate 6.96 min, while at (S, S) chiral stationary phase it will be eluted at 6.10 min.

02

Step 2: (R)-enantiomer not observed with the (R,R)-stationary phase

Part (b)

At (S, S) stationary phase, the small peak for (R)-gimatecan (at 6-. min) is separated from the big (S)-gimatecan peak (at 6.96 min). The area between the two peaks can be integrated, so we can compare with each other. At (R, R) stationary phase, we see (S)- gimatecan peak (6.1 min), while there is no (R)-gimatecan peak (it is lost beneath the tail of (S-gimatecan). Chromatography enables us to locate where enantiomer is eluted.

03

Relative retention (a) for the two enantiomers

Part (c)

First, we need to calculatetmfrom retention factor of each enantiomer:

k=tr-tmtmtm=trk+1

For (S)-gimatecan:

tm=6.96min1.50+1tm=2.784min

For (R)-gimatecan:

tm=6.10min1.22+1tm=2.784min

The averagetmis:

tm=6.10min1.22+1tm=2.766min

The adjusted retention time is:

tr'=tr-tm

For (R)-gimatecan:

tr1'=6.10-2.766mintr1'=3.334min

For (S)-gimatecan:

tr2'=6.96-2.766mintr2'=4.194min

The relative retention can be calculated using the formula:

α=tr2'tr2'=4.1943.334=1.26

04

Signal returns to baseline before the next peak begins

Part (d)

The resolution can be calculated using the formula:

resolution=N4.α-1α.k1+kresolution=68004.1.26-11.26.1.501+1.50resolution=2.55

If the peaks were symmetric, this resolution would provide adequate baseline separation.

Here, the final result of part(a), part(b), part(c), part(d) is

(a) Chiral stationary phase it will be eluted at 6.10 min.

(b) Chromatography enables us to locate where enantiomer is eluted.

(c)α=1.26

(d) resolution = 2.55

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with Vaia!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

Astandard solution containing 6.3×10-8Miodoacetone and 2.0×10-7Mp-dichlorobenzene (an internal standard) gave peak areas of 395 and 787, respectively, in a gas chromatogram. A 3.00-mlunknown solution of iodoacetone was treated with 0.100mLof 1.6×10-5Mp-dichlorobenzene and the mixture was diluted to. Gas chromatography gave peak areas of 633 and 520 for iodoacetone and p-dichlorobenzene, respectively. Find the concentration of iodoacetone in the 3.00mLof original unknown.

Why is split less injection used with purge and trap sample preparation?

(a) When a solution containing234mg of pentanol (FM 88.15) and237mg of 2,3 -dimethyl-2-butanol (FM 102.17) in10.0ml was separated, relative peak areas were pentanol: 2,3 -dimethyl-2-butanol = 0.913 : 1.00. Considering pentanol to be the internal standard, find the response factor for 2,3 -dimethyl-2-butanol.

(b) Use Equation 24-8 to find the areas for pentanol and 2,3 -dimethyl-2-butanol in Figure 24-8.

(c) The concentration of pentanol internal standard in the unknown solution was93.7mM . What was the concentration of 2,3 -dimethyl2-butanol?

Retention time depends on temperature, T, according to the equation log t’r =(a/T) + b, where a and b are constants for a specific compound on a specific column. A compound is eluted from a gas chromatography column at an adjusted retention time t’r =15.0 min when the column temperature is 373K. At 363 K, t9r 5 20.0 min. Find the parameters a and b and predict t’r at 353K

Consider the chromatography of n-c12H26on a 25 m × 0.53 mm open tubular column of 5% phenyl–95% methyl polysiloxane with a stationary phase thickness of 3.0 μmand He carrier gas at 125ºC. The observed retention factor for n-c12H26is 8.0. Measurements were made of plate height, H, at various values of linear velocity,μxm/s. A least-squares curve through the data points is given by

localid="1654864230381" H(m)=(6.0×10-5m2/s)/μx+(2.09×10-3s)μxthecoefficientsofthevanDeemterequation,findthediffusioncoefficientofn-c12H26inthemobileandstationaryphases.Whyisoneofthesediffusioncoefficientssomuchgreaterthantheother?

See all solutions

Recommended explanations on Chemistry Textbooks

View all explanations

What do you think about this solution?

We value your feedback to improve our textbook solutions.

Study anywhere. Anytime. Across all devices.

Sign-up for free