Fluorescent derivatives of amino acids separated by capillary zone electrophoresis had migration times with the following order: arginine (fastest) , phenylalanine , asparagine , serine , glycine(slowest). Explain why arginine has the shortest migration time.

Short Answer

Expert verified

Considering that arginine is the least negative of the listed amino acids, it would move towards the anode slower and towards the cathode it would be the fastest.

Step by step solution

01

Define amino acid:

Amino acids are molecules that combine to form proteins. Amino acids and proteins are the building blocks of life.

02

Fluorescent derivatives of amino acids:

Fluorescent derivatives of amino acids are separated by capillary zone electrophoresis with the following order: arginine (fastest), phenylalanine, asparagine, serine, and glycine (slowest).

03

 Find arginine has the shortest migration time:

The listed compounds in the task are all amino acids, where only arginine contains positive side chain, whereas other amino acids have negatively charged side chains.

04

Explanation for the arginine:

Considering that arginine is the least negative of the listed amino acids, it would move towards the anode slower and towards the cathode (electroosmosis) it would be the fastest.

Unlock Step-by-Step Solutions & Ace Your Exams!

  • Full Textbook Solutions

    Get detailed explanations and key concepts

  • Unlimited Al creation

    Al flashcards, explanations, exams and more...

  • Ads-free access

    To over 500 millions flashcards

  • Money-back guarantee

    We refund you if you fail your exam.

Over 30 million students worldwide already upgrade their learning with Vaia!

One App. One Place for Learning.

All the tools & learning materials you need for study success - in one app.

Get started for free

Most popular questions from this chapter

To obtain the best separation of two weak acids in capillary electrophoresis, it makes sense to use the pH at which their charge difference is greatest. Prepare a spreadsheet to examine the charges of malonic and phthalic acid as a function of pH. At what pH is the difference greatest?

Decomposition of dithionite(S2O42-).was studied by chromatography on an anion-exchange column eluted with 20mM tri-sodium 1, 3, 6-napthalenetrisulfonate in 90 vol%H2O/10

vol%CH3CNwith ultraviolet detection at 280 nm. A solution of sodium dithionite stored for 34 days in the absence of air gave five peaks identified asSO32-,SO42-,S2O32-,S2O42-andS2Os2-All the peaks had a negative absorbance. Explain why.

The exchange capacity of an ion-exchange resin can be defined as the number of moles of charged sites per gram of dry resin. Describe how you would measure the exchange capacity of an anion-exchange resin by using standard NaOH, standard HCl, or any other reagent you wish.

The observed behavior of benzyl alcohol (C6H5CH2OH) in capillary electrophoresis is given here. Draw a graph showing the number of plates versus the electric field and explain what happens as the field increases.

Figure 26-24 shows the effect on resolution of increasing voltage from 28 to120kV.

(a) What is the expected ratio of migration times (t120kV/t28kV)in the two experiments? Measure the migration times for peak 1 and find the observed ratio.

(b) What is the expected ratio of plates (N120kV/N28kV)in the two experiments?

(c) What is the expected ratio of bandwidths(ฯƒ120kV/ฯƒ28kV)?

(d) What is the physical reason why increasing voltage decreases bandwidth and increases resolution?

See all solutions