Chapter 21: Problem 55
The nurse is preparing to monitor the client's central venous pressure. Which position would provide the most reliable measurement of the CVP? A. Supine B. High Fowler's C. Left Sims' D. Prone
Short Answer
Expert verified
Answer: A. Supine.
Step by step solution
01
Reviewing positions
First, let's briefly review the four given positions:
1. Supine: Lying flat on the back, facing upwards. It is the most common position for monitoring vital signs.
2. High Fowler's: Sitting upright at a 90-degree angle, with the knees either bent or straight.
3. Left Sims': Lying on the left side with the right leg bent and drawn up towards the chest, and the left arm behind the body.
4. Prone: Lying face-down, on the stomach.
02
Central Venous Pressure (CVP)
Central venous pressure is the measurement of blood pressure in the right atrium of the heart or in the large veins close to the heart. It is a vital indicator of fluid balance, venous return, and the function of the right side of the heart.
03
Ideal position for CVP measurement
To obtain an accurate and reliable measurement of CVP, it is crucial to ensure the patient is in a position where the right atrium of the heart is at the same level as the external reference point (generally the mid-axillary line, at the level of the fourth intercostal space). The best position for achieving this is the supine position.
04
Explaining other positions
Let's briefly explain why the other positions are not ideal for accurate CVP measurements:
- High Fowler's: In this position, the elevation of the upper body causes the right atrium to be lower than the external reference point, which can lead to decreased CVP measurements.
- Left Sims': This position may cause compression of large veins, potentially affecting venous return and leading to inaccurate CVP measurements.
- Prone: This position makes it difficult to access the central venous catheter, and the pressure exerted on the anterior chest wall can affect the accuracy of CVP measurements.
In conclusion, based on the information provided:
05
Answer
The best position for obtaining a reliable measurement of central venous pressure is A. Supine.
Unlock Step-by-Step Solutions & Ace Your Exams!
-
Full Textbook Solutions
Get detailed explanations and key concepts
-
Unlimited Al creation
Al flashcards, explanations, exams and more...
-
Ads-free access
To over 500 millions flashcards
-
Money-back guarantee
We refund you if you fail your exam.
Over 30 million students worldwide already upgrade their learning with Vaia!
Key Concepts
These are the key concepts you need to understand to accurately answer the question.
CVP Monitoring
Central Venous Pressure (CVP) Monitoring is a critical diagnostic tool that provides information about a patient's blood volume, cardiac function, and the ability of the heart to pump effectively. It involves measuring the pressure in the thoracic vena cava near the right atrium of the heart. This measurement is essential in managing patients with complex fluid and hemodynamic status, including those with heart failure, kidney failure, or on certain types of medications.
Accurate CVP readings can guide interventions such as fluid resuscitation in critically ill patients, adjusting the dosages of medications that affect the heart and blood vessels, and monitoring patients undergoing major surgeries.
For a more comprehensive understanding and optimal accuracy, it is important to standardize the procedure and ensure the use of appropriate equipment calibrated to the correct zero-reference level, typically aligned with the patient's mid-axillary line at the fourth intercostal space.
Accurate CVP readings can guide interventions such as fluid resuscitation in critically ill patients, adjusting the dosages of medications that affect the heart and blood vessels, and monitoring patients undergoing major surgeries.
For a more comprehensive understanding and optimal accuracy, it is important to standardize the procedure and ensure the use of appropriate equipment calibrated to the correct zero-reference level, typically aligned with the patient's mid-axillary line at the fourth intercostal space.
Patient Positioning for CVP
Proper patient positioning is crucial for obtaining accurate and consistent measurements of Central Venous Pressure (CVP). The ideal position to measure CVP is the supine position, where the patient lies flat on their back. This position aligns the right atrium with the external reference point used for CVP readings, allowing for a reliable measurement.
It is also vital to maintain the patient's body in a neutral position without any bends or pressure points that can affect venous return. The head must be aligned with the body without tilting or rotation, as these movements can impact the pressure readings. It is recommended to use a soft, flat surface to support the patient's back and ensure comfort during the procedure.
When positioning patients with respiratory distress or other conditions that make lying flat uncomfortable, adjustments can be made as long as the zero-reference level for the CVP transducer remains accurate.
It is also vital to maintain the patient's body in a neutral position without any bends or pressure points that can affect venous return. The head must be aligned with the body without tilting or rotation, as these movements can impact the pressure readings. It is recommended to use a soft, flat surface to support the patient's back and ensure comfort during the procedure.
When positioning patients with respiratory distress or other conditions that make lying flat uncomfortable, adjustments can be made as long as the zero-reference level for the CVP transducer remains accurate.
Nursing Interventions
Nursing interventions related to Central Venous Pressure Measurement encompass a range of actions aimed at ensuring patient safety, accuracy of the procedure, and a prompt response to the results.
A nurse must first establish and maintain a sterile field to prevent infection as the measurement involves accessing central venous catheters. Continuous monitoring for potential complications such as catheter occlusion, infection, or air embolism is imperative.
Nurses play a pivotal role in patient education, helping patients recognize signs of complications and teaching them about fluid management, if appropriate.
A nurse must first establish and maintain a sterile field to prevent infection as the measurement involves accessing central venous catheters. Continuous monitoring for potential complications such as catheter occlusion, infection, or air embolism is imperative.
Preparation and Follow-Up
Prior to CVP monitoring, the nurse should explain the procedure to the patient, ensuring that they understand why it's being done and what to expect. After the measurement, proper documentation and analysis of CVP trends are essential. The nurse should also be ready to adjust fluid management or notify the physician if the CVP readings indicate potential hemodynamic imbalance.Nurses play a pivotal role in patient education, helping patients recognize signs of complications and teaching them about fluid management, if appropriate.